Skip to main content
European Commission logo
ESARDA
  • Scientific paper

Improving the Confidence Associated with Passive Total Neutron Counting in the Nuclear Weapon Disarmament Verification Process

ESARDA Bulletin - The International Journal of Nuclear Safeguards and Non-Proliferation

Details

Identification
ISSN: 1977-5296, DOI: 10.3011/ESARDA.IJNSNP.2023.1
Publication date
28 March 2023
Author
Joint Research Centre

Description

Volume: 65, December 2023, pages 2-9

Authors: Ville Bogdanoff1, Kari Peräjärvi2

1University of Jyvaskyla, Radiation and 2Nuclear Safety Authority (STUK)

Abstract: Passive total neutron counting is an important tool in the nuclear weapon disarmament monitoring and verification process proposed by the International Partnership for Nuclear Disarmament Verification (IPNDV). In the process, neutron measurements of given treaty accountable items (TAIs) are repeated multiple times in different locations and environments, and the measured neutron count rates are expected to remain unchanged. However, neutrons are heavily scattered in the environment, and the change in location or geometry of the environment can produce varying results in neutron measurements which can deteriorate the confidence of passive total neutron counting. In this paper, we have studied different kinds of neutron detection instruments and methods in various environments to determine the effects of the environment on passive total neutron counting and to develop recommendations and procedures to minimize and take these environmental factors into account. As a result, the moderated 3He propor tional counter was the most promising type of instrument in terms of how the change in an environment impacted the measured neutron count rates. However, even with the 3He counter, the environmental influence increased rapidly with the sourceto- detector distance (SDD). For example, with one-meter, two-meter, and three-meter SDDs, the maximum difference in count rates between outdoor and indoor measurements was 10.06(7) percent, 18.6(3) percent, and 28.1(5) percent, respectively. To mitigate the impact of the measurement environment, we propose to use a bare 252Cf reference source measured in the same geometries as the nuclear TAIs to estimate the influence of the environment on the measured neutron count rates. Using this technique in the same conditions as above produces indoor predictions that differ by 2.55(3) percent with a one-meter SDD, 0.334(5) percent with two-meter SDD and 1.93(4) percent with a three-meter SDD from the actual indoor measurements.

Keywords: nuclear disarmament; IPNDV; neutron counting; neutron scattering

Reference guideline:

Bogdanoff, V., Peräjärvi, K. (2023, December). Improving the Confidence Associated with Passive Total Neutron Counting in the Nuclear Weapon Disarmament Verification Process ESARDA Bulletin - The International Journal of Nuclear Safeguards and Non-proliferation, 65, 2-9. https://doi.org/10.3011/ESARDA.IJNSNP.2023.1

THMB_B_65-1

Files

  • 28 MARCH 2023
Improving the Confidence Associated with Passive Total Neutron Counting in the Nuclear Weapon Disarmament Verification Process